Please note that our Terms & Conditions and Privacy Notice are applicable.
On Promotion in Home & Garden
Pay OnlineSECURELYEASY DELIVERY OR COLLECTION
Buy with confidence. Secure payment options & nationwide delivery. Learn more
Filter & refine
Clear All
Suggested
Results for geyser element in "geyser element" in Home & Garden Supplies in South Africa in South Africa
1
R 476.93
SavedSave
Please note that shipping and installation is not included.Vontron RO Menbrane 2012 100 GPD
TESTING CONDITIONS:
Testing Pressure ……………………………….......… 100 psi (0.41MPa)The temperature of Testing Solution ………….…….. 25℃The concentration of Testing Solution (NaCl) ……… 250ppmThe pH of Testing Solution …………………….…….. 6.5~8Recovery of Single Element………….......…….……. 15%
Parameters Of A Vontron RO Menbrane 2012 100 GPD
250 TDS Filtered (5µ), De-Chlorinated, Municipal Feed Water, 77˚F,
40% Permeate Recovery, 6.5-7.0 pH Range, at the Specified Operating
Pressure.Data Taken After 30 Minutes of Operation.Maximum Pressure Drop for Each Element is 10psi.Minimum Salt Rejection is 96%.
Permeate Flow for Individual Elements may vary ± 20%.While in storage, membrane elements must be kept sealed and moist. While drying out may occur and damage the membrane permanently. To prevent elements from freezing or being exposed to direct sunlight, we take additional measures. Well tested elements are vacuum-sealed in a polyethylene oxygen barrier bag containing 2012 100 GPD Membrane Preservative and then packaged in a cardboard box. Discard the permeate for the first twenty-four hours of operation. Do not use the first full tank of permeate for drinking or food preparation. The permeate flow (product water flow) varies with feed water temperature. Review a Temperature Correction Chart. For membrane warranty information, please
contact the manufacturer.
Important Operation Notes:
When this product is used for the first time, permeate water obtained from the first hour of use should be discarded.Also keep elements moist at all times after initial wetting.If you do not strictly follow the operating limits and guidelines stated in this Product Information Bulletin, the Limited Warranty will be void.To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution. Rinse out the preservative before use.The OEM is fully responsible for the effects of incompatible chemicals and lubricants on elements. The use of any such chemicals or lubricants will void the Limited Warranty.
4d
Mbombela / Nelspruit1
R 1,106.62
SavedSave
Please note that shipping and installation is not included.TESTING CONDITIONS:
Testing Pressure ………………………………… 100 psi (0.41MPa)The temperature of Testing Solution ……………….. 25℃The concentration of Testing Solution (NaCl) ……… 500 ppmThe pH of Testing Solution ………………………….. 6.5~8.5Recovery of Single Element……………………. 15%
Parameters Of A Domestic Reverse Osmosis Membrane
250 TDS Filtered (5µ), De-Chlorinated, Municipal Feed Water, 77˚F, 40% Permeate Recovery, 6.5-7.0 pH Range, at the Specified Operating Pressure.Data Taken After 30 Minutes of Operation.Maximum Pressure Drop for Each Element is 10psi.Minimum Salt Rejection is 96%.
Firstly Permeate Flow for Individual Elements may vary ± 20%. While in storage, membrane elements must be kept sealed and moist. Consequently drying out may occur and damage the membrane permanently. Unless you must prevent elements from freezing or being exposed to direct sunlight. We tested elements are vacuum-sealed in a polyethylene oxygen barrier bag containing. Vontron RO Membrane 3012 300 GPD Preservative and then packaged in a cardboard box.
Discard the permeate for the first twenty-four hours of operation. Do not use the first full tank of permeate for drinking or food preparation. The permeate flow (product water flow) varies with feed water temperature. Review a Temperature Correction Chart. For membrane warranty information, please contact the manufacturer.
Important Operation Notes:
When someone uses this product for the first time. Discard water obtained from the first hour of use, as it should permeate instead.While keep elements moist at all times after initial wetting.If operating limits and guidelines given in this Product Information Bulletin are not strictly followed, the Limited Warranty will be null and void.To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution. Rinse out the preservative before use.The OEM is fully responsible for the effects of incompatible chemicals and lubricants on elements. The use of any such chemicals or lubricants will void the Limited Warranty.
3d
Mbombela / Nelspruit1
R 4,567.85
SavedSave
Please note that shipping and installation is not included.Vontron MembranesVontron Reverse Osmosis Membrane ULP21-4021 series of ultra-low pressure aromatic polyamide compound membrane element newly eveloped by Vontron Membrane Technology Co., Ltd. Can work under ultra low pressure to reach as high permeate flow and rejection same as regular low-pressure membrane element, and is applicable to desalination of surface water and underground water. It operates under approximately two thirds of the operating pressure of regular low-pressure composite membranes, which
can decrease the investment costs for such relevant facilities as pumps, pipelines, and containers, etc. and the operating cost for the RO system, thus increasing the economic efficiency.Applicable to desalination treatment of those water sources with NaCl lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, ULP series membrane elements are mainly applicable to such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production.
4d
Mbombela / Nelspruit1
R 2,905.04
SavedSave
Please note that shipping and installation is not included.Vontron Reverse Osmosis Membrane ULP21-4021 series of extremely low-pressure aromatic polyamide compound membrane elements can work under ultra-low pressure to reach as high permeate flow and salt rejection as regular low-pressure membrane elements can, and is applicable to desalination of surface water and underground water.It operates under approximately half the operating pressure of a regular low-pressure composite membrane and achieves a salt rejection rate of up to 99.0%, which can decrease the investment costs for such relevant facilities as pump, piping, and container, etc. and the operating cost for the RO system, thus increasing the economic efficiency.Being suitable for the desalination treatment of those water sources with low salinity not requiring high salt rejection such as surface water, underground water, tap water, and municipal water, which have a salt concentration lower than 1000 ppm, XLP series of membrane elements is particularly applicable to the second-pass desalination with two-pass RO system, and is mainly applied to numerous applications of various scales, such as pure water production, boiler water replenishment, foodstuff processing, and pharmaceutical production.
4d
Mbombela / Nelspruit1
R 158.70
SavedSave
Please note that shipping and installation is not included.
Type
1812 Reverse Osmosis Membrane Housing
Cap Color
White
Housing Color
White
Inlet and Outlet
1/4″
Threaded
NPT
Operating pressure
Max. 125 PSI
Operating temperature
4 ~ 38℃(40 ~ 100℉)
1812 100 GPD Super flow – The Reverse Osmosis Membrane element is designed for the treatment of low-salinity water resources such as tap water, well water, etc. Working under extra-low pressure, it is applicable to water purifying devices for residence, hospitals, and laboratories.Notes: Permeate of a single element may vary within [-20%] ~ [+20%]Dimensions: 1.0 inch = 25.4 mm
TESTING CONDITIONS:
Testing Pressure ………………………………… 60 psi (0.41MPa)(0.41MPa)The temperature of Testing Solution ……………….. 25℃The concentration of Testing Solution (NaCl) ……… 250 ppmthe pH of Testing Solution ………………………….. 6.5~8.5Recovery of Single Element……………………. 15%
Reverse osmosis (RO) membrane elements for home drinking water are the industry’s most reliable. Advanced membrane technology and automated fabrication allow these elements to deliver consistent performance that equipment suppliers, water treatment dealers, and residential customers can rely on. Membrane elements are shipped dry for convenient handling and long shelf-life. These elements are NSF/ANSI Standard 58 listed.Equipment suppliers can take advantage of the membrane’s Standard 58 listing and participation in the NSF Data Transfer Protocol to reduce costs for reduction claims for their systems. Reverse Osmosis home drinking water elements are rated a 50 psi and will purify about 20% more water than competitive elements rated at 60 psi (please see reference charts on page two for more information).
Operating Limits
Membrane Type Polyamide: Thin-Film CompositeMaximum Operating Temperature: 113°F (45°C)Maximum Operating Pressure: 300 PSIG (21 bar)Maximum Feed Flow Rate: 2.0 GPM (7.6 lpm)pH Range, Continuous Operation: 2 – 11pH Range, Short-Term Cleaning: (30 min.)b 1 – 13Maximum Feed Silt Density Index (SDI): 5Free Chlorine Tolerance: < 0.1 ppm
The maximum temperature for continuous operation above pH 10 is 95°F (35°C).Refer to Cleaning Guidelines in specification sheet 609-23010.Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure.Since oxidation damage is not covered under warranty, Film Tech recommends removing residual free chlorine by pretreatment prior to membrane exposure. Please refer to technical bulletin 609-22010 for more information.
3d
Mbombela / Nelspruit1
R 11,164.34
SavedSave
Please note that shipping and installation is not included.Firstly Vontron reverse osmosis membrane ULP22-8040 ultra-low pressure aromatic polyamide compound membrane element. Newly developed by Vontron Membrane Technology Co.Ltd. Can work under ultra low pressure to reach as high permeate flow and rejection same as regular low-pressure membrane element.Is applicable to desalination of surface water and underground water. It operates under approximately two thirds of the operating pressure of regular low-pressure composite membranes, which can decrease the investment costs for such relevant facilities as pumps, pipelines, and containers, etc. and the operating cost for the RO system, thus increasing the economic efficiency.Applicable to desalination treatment of those water sources with NaCl lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, ULP series membrane elements are mainly applicable to such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production.
The LP (low pressure) series of aromatic polyamide compound membrane element developed by Vontron Membrane Technology Co., Ltd. has the properties of low-pressure operation, high permeate flow and excellent desalination and is applicable to desalination of brackish water. Besides, it is particularly applicable to fabrication of high-purity water for electronic industry and electric power industry owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.Being suitable for desalting such water sources as surface water (NaCl ≤10000ppm), underground water, tap water and municipal water, etc., LP series is mainly applicable to treatment of various industrial water such as industrial-purpose pure water, boiler water replenishment in power plants, and can be also applied to such brackish water applications, such as treatment of high-concentration saline waste water and production of beverage-purpose water.
4d
Mbombela / Nelspruit1
R 3,195.67
SavedSave
Please note that shipping and installation is not included.PRODUCT DESCRIPTION
First thing to remember is that the Membrane housing First Line 4040 x 2 elements FRP – same side port is designed for continuous, long-term use in reverse osmosis and ultra filtration applications. In industrial and commercial water treatment systems at a pressure of 300 PSI.
The permissible working range is 10 ℃ to 49℃.
The pressure of the membrane housing penetration test is 1.5 times the standard pressure.PRODUCT BENEFIT
100,000 cycles.Blast test at 6 times working pressure.Perform 100% quality inspection and cleaning prior to final packaging and delivery to the customerCompetitive PriceHeavy Duty Industrial Grade Fiberglass (FRP) 4″ x 40″ Membrane Pressure Vessel Housing Will not rust.Fits all standard 4040 membranes.RO UF & NF (Reverse Osmosis, Ultrafiltration, & Nanofiltration)300 psi3/4″ Feed and Drain Ports (FNPT)1/2″ Permeate Ports (FNPT) O-ring End Port Caps Included.Stainless Clamps, and Stainless Hardware Included.Brackets Included.Fits all 4″ x 40″ membranesOverall Size of product is 46″ tall x 5″ diameterSpecifically The Shipping Dimensions are 47″ x 6″ x 6″Membrane housing First Line 4040 x 2 elements FRP – same side port
4″ FRP membrane housingMaterial: FRPEnd cap material: ABSMax. working pressure: 300psi, 450psi, 600psi, 800psi,1000psiInlet port: 3/4″Outlet port: 1/2″
So, the membrane housing 4040 FRP is a pressure vessel. In effect which is used for loading membrane elements in a RO water treatment system. The material of the membrane housing is divided into three types, such as FRP, stainless steel, and PVC.
Membrane housing is relatively standard across the industry, it is made with high-quality components and o-rings, which is the perfect option for building your RO/DI system or replacing worn-out membrane housing.
The membrane pressure vessels or membrane housings of Ro Aqua can achieve a variety of sizes, cover styles, pressure levels, and side or end inlet designs.
3d
Mbombela / Nelspruit1
R 4,828.90
SavedSave
Please note that shipping and installation is not included.First thing to remember is that the membrane housing First Line 4040 x 3 elements FRP – 3 side port is designed for continuous, long-term use in reverse osmosis and ultra filtration applications. In industrial and commercial water treatment systems at a pressure of 300 PSI.The permissible working range is 10 ℃ to 49℃. The pressure of the membrane housing penetration test is 1.5 times the standard pressure.
PRODUCT BENEFIT
100,000 cycles.Blast test at 6 times working pressure.Perform 100% quality inspection and cleaning prior to final packaging and delivery to the customerCompetitive PriceHeavy Duty Industrial Grade Fiberglass (FRP) 4″ x 40″ Membrane Pressure Vessel Housing Will not rust.Fits all standard 4040 membranes.RO UF & NF (Reverse Osmosis, Ultra filtration, & Nano filtration)300 psi3/4″ Feed and Drain Ports (FNPT)1/2″ Permeate Ports (FNPT) O-ring End Port Caps Included.Stainless Clamps, and Stainless Hardware Included.Brackets Included.Fits all 4″ x 40″ membranesOverall Size of product is 46″ tall x 5″ diameterSpecifically The Shipping Dimensions are 47″ x 6″ x 6″Membrane housing First Line 4040 x 3 elements FRP – 3 side port
4″ FRP membrane housingMaterial: FRPEnd cap material: ABSMax. working pressure: 300psi, 450psi, 600psi, 800psi,1000psiInlet port: 3/4″Outlet port: 1/2″So, the membrane housing 4040 FRP is a pressure vessel. In effect which is used for loading membrane elements in a RO water treatment system. The material of the membrane housing is divided into three types, such as FRP, stainless steel, and PVC.Membrane housing is relatively standard across the industry, it is made with high-quality components and o-rings, which is the perfect option for building your RO/DI system or replacing worn-out membrane housing. The membrane pressure vessels or membrane housings of RO Aqua can achieve a variety of sizes, cover styles, pressure levels, and side or end inlet designs.
3d
Mbombela / Nelspruit1
R 17,363.16
SavedSave
Please note that shipping and installation is not included.Vontron sea water reverse osmosis membrane SW22-8040 descriptionSW Series is always used for sea water desalination. It can improve permeate flow by optimizing membrane element structure. This product has the features of high rejection rate, stable performance, low operating cost and small equipment investment. It should be used to obtain qualified drinking water from sea water.Application
Seawater desalination.Water reuse and near-zero discharge, for example: chemical industry, iron and steel industry, electric power industry, etc.Concentration of high-concentration materials, for example:pharmaceuticals materials, food and beverage materials, etc.
Model
Stable Rejection Rate(%)
Permeate Flow GPD(m3/d)
Active Membrane Area ft2(m2)
Feed Spacer Thickness mil
SW22-8040
99,9
6000(22,7)
400(37,2)
28
Operating Conditions and Limits
Maximum operating pressure psi(MPa):1200 (8,28)
Maximum feed water temperature ℃:45
Maximum inlet flow rate m3/h:17
Maximum concentration of free chlorine mg/L:0,1
Maximum pressure drop per element psi(MPa):15 (0,1)
Allowed pH range for feed water in operation:2-11
Allowed pH range for chemical cleaning:1-23
Maximum feed water flow SDI15:5
4d
Mbombela / Nelspruit1
R 6,088.28
SavedSave
Please note that shipping and installation is not included.First thing to remember is that the membrane housing First Line 4040 x 4 elements FRP – opposite side port is designed for continuous, long-term use in reverse osmosis and ultra filtration applications. In industrial and commercial water treatment systems at a pressure of 300 PSI.The permissible working range is 10 ℃ to 49℃. The pressure of the membrane housing penetration test is 1.5 times the standard pressure.PRODUCT BENEFIT100,000 cycles.Blast test at 6 times working pressure.Perform 100% quality inspection and cleaning prior to final packaging and delivery to the customerCompetitive PriceHeavy Duty Industrial Grade Fiberglass (FRP) 4″ x 160″ Membrane Pressure Vessel Housing Will not rust.Fits all standard 4040 membranes.RO UF & NF (Reverse Osmosis, Ultra filtration, & Nano filtration)300 psi3/4″ Feed and Drain Ports (FNPT)1/2″ Permeate Ports (FNPT) O-ring End Port Caps Included.Stainless Clamps, and Stainless Hardware Included.Brackets Included.Fits all 4″ x 40″ membranes
Membrane housing First Line 4040 x 3 elements FRP – opposite side port
4″ FRP membrane housingMaterial: FRPEnd cap material: ABSMax. working pressure: 300psi, 450psi, 600psi, 800psi,1000psiInlet port: 3/4″Outlet port: 1/2″So, the membrane housing 4040 FRP is a pressure vessel. In effect which is used for loading membrane elements in a RO water treatment system. The material of the membrane housing is divided into three types, such as FRP, stainless steel, and PVC.Membrane housing is relatively standard across the industry, it is made with high-quality components and o-rings, which is the perfect option for building your RO/DI system or replacing worn-out membrane housing. The membrane pressure vessels or membrane housings of RO Aqua can achieve a variety of sizes, cover styles, pressure levels, and side or end inlet designs.
3d
Mbombela / Nelspruit1
R 2,883.92
SavedSave
Please note that shipping and installation is not included.
PRODUCT DESCRIPTION
First thing to remember is that the membrane housing First Line 4040 x 2 elements FRP – end port is designed for continuous, long-term use in reverse osmosis and ultra filtration applications. In industrial and commercial water treatment systems at a pressure of 300 PSI.The permissible working range is 10 ℃ to 49℃. The pressure of the membrane housing penetration test is 1.5 times the standard pressure.PRODUCT BENEFIT100,000 cycles.Blast test at 6 times working pressure.Perform 100% quality inspection and cleaning prior to final packaging and delivery to the customerCompetitive PriceHeavy Duty Industrial Grade Fiberglass (FRP) 4″ x 40″ Membrane Pressure Vessel Housing Will not rust.Fits all standard 4040 membranes.RO UF & NF (Reverse Osmosis, Ultrafiltration, & Nanofiltration)300 psi3/4″ Feed and Drain Ports (FNPT)1/2″ Permeate Ports (FNPT) O-ring End Port Caps Included.Stainless Clamps, and Stainless Hardware Included.Brackets Included.Fits all 4″ x 40″ membranesOverall Size of product is 46″ tall x 5″ diameterSpecifically The Shipping Dimensions are 47″ x 6″ x 6″Membrane housing First Line 4040 x 2 elements FRP – end port
4″ FRP membrane housingMaterial: FRPEnd cap material: ABSMax. working pressure: 300psi, 450psi, 600psi, 800psi,1000psiInlet port: 3/4″Outlet port: 1/2″So, the membrane housing 4040 FRP is a pressure vessel. In effect which is used for loading membrane elements in a RO water treatment system. The material of the membrane housing is divided into three types, such as FRP, stainless steel, and PVC.
Membrane housing is relatively standard across the industry, it is made with high-quality components and o-rings, which is the perfect option for building your RO/DI system or replacing worn-out membrane housing.The membrane pressure vessels or membrane housings of Ro Aqua can
achieve a variety of sizes, cover styles, pressure levels, and side or
end inlet designs.
3d
Mbombela / Nelspruit1
R 3,467.66
SavedSave
Please note that shipping and installation is not included.
PRODUCT DESCRIPTION
First thing to remember is that the membrane housing First Line 4040 x 2 elements FRP – opposite side port is designed for continuous, long-term use in reverse osmosis and ultra filtration applications. In industrial and commercial water treatment systems at a pressure of 300 PSI.The permissible working range is 10 ℃ to 49℃. The pressure of the membrane housing penetration test is 1.5 times the standard pressure.PRODUCT BENEFIT
100,000 cycles.Blast test at 6 times working pressure.Perform 100% quality inspection and cleaning prior to final packaging and delivery to the customerCompetitive PriceHeavy Duty Industrial Grade Fiberglass (FRP) 4″ x 40″ Membrane Pressure Vessel Housing Will not rust.Fits all standard 4040 membranes.RO UF & NF (Reverse Osmosis, Ultrafiltration, & Nano filtration)300 psi3/4″ Feed and Drain Ports (FNPT)1/2″ Permeate Ports (FNPT) O-ring End Port Caps Included.Stainless Clamps, and Stainless Hardware Included.Brackets Included.Fits all 4″ x 40″ membranesOverall Size of product is 46″ tall x 5″ diameterSpecifically The Shipping Dimensions are 47″ x 6″ x 6″Membrane housing First Line 4040 x 2 elements FRP – opposite side port
4″ FRP membrane housingMaterial: FRPEnd cap material: ABSMax. working pressure: 300psi, 450psi, 600psi, 800psi,1000psiInlet port: 3/4″Outlet port: 1/2″
So, the membrane housing 4040 FRP is a pressure vessel. In effect which is used for loading membrane elements in a RO water treatment system. The material of the membrane housing is divided into three types, such as FRP, stainless steel, and PVC.
Membrane housing is relatively standard across the industry, it is made with high-quality components and o-rings, which is the perfect option for building your RO/DI system or replacing worn-out membrane housing.The membrane pressure vessels or membrane housings of Ro Aqua can achieve a variety of sizes, cover styles, pressure levels, and side or end inlet designs.
3d
Mbombela / Nelspruit1
R 4,467.47
SavedSave
Please note that shipping and installation is not included.First thing to remember is that the membrane housing First Line 4040 x 2 elements FRP – opposite side port is designed for continuous, long-term use in reverse osmosis and ultra filtration applications. In industrial and commercial water treatment systems at a pressure of 300 PSI.The permissible working range is 10 ℃ to 49℃. The pressure of the membrane housing penetration test is 1.5 times the standard pressure.
PRODUCT BENEFIT
100,000 cycles.Blast test at 6 times working pressure.Perform 100% quality inspection and cleaning prior to final packaging and delivery to the customerCompetitive PriceHeavy Duty Industrial Grade Fiberglass (FRP) 4″ x 40″ Membrane Pressure Vessel Housing Will not rust.Fits all standard 4040 membranes.RO UF & NF (Reverse Osmosis, Ultra filtration, & Nano filtration)300 psi3/4″ Feed and Drain Ports (FNPT)1/2″ Permeate Ports (FNPT) O-ring End Port Caps Included.Stainless Clamps, and Stainless Hardware Included.Brackets Included.Fits all 4″ x 40″ membranesOverall Size of product is 46″ tall x 5″ diameterSpecifically The Shipping Dimensions are 47″ x 6″ x 6″Membrane housing First Line 4040 x 3 elements FRP – opposite side port
4″ FRP membrane housing
Material: FRPEnd cap material: ABSMax. working pressure: 300psi, 450psi, 600psi, 800psi,1000psiInlet port: 3/4″Outlet port: 1/2″So, the membrane housing 4040 FRP is a pressure vessel. In effect which is used for loading membrane elements in a RO water treatment system. The material of the membrane housing is divided into three types, such as FRP, stainless steel, and PVC.Membrane housing is relatively standard across the industry, it is made with high-quality components and o-rings, which is the perfect option for building your RO/DI system or replacing worn-out membrane housing. The membrane pressure vessels or membrane housings of Ro Aqua can
achieve a variety of sizes, cover styles, pressure levels, and side or
end inlet designs.
3d
Mbombela / Nelspruit1
R 3,343.46
SavedSave
Please note that shipping and installation is not included.Vontron Reverse Osmosis Membrane ULP21-4040 series of ultra-low pressure aromatic polyamide compound membrane element newly eveloped by Vontron Technology Co. Ltd.
Membrane can operate under ultra low pressure to reach as high permeate flow and salt rejection as regular low-pressure membrane element can and is applicable to desalination of surface water and underground water.
It operates under approximately 2 thirds of the operating pressure of regular low-pressure composite membranes, and achieves a salt rejection rate of up to 99.5%, which can decrease the investment costs for relevant facilities such as pumps, piping and the operating cost for the RO system, thus increasing the economic efficiency.
Being suitable for the desalting treatment of those water sources with salt concentration lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, etc., ULP series membrane elements are mainly applicable to numerous applications of various scales, such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production, etc.Vontron Reverse Osmosis Membrane ULP21-4040
The Vontron Membrane Range developed by Vontron Technology Co. Ltd. has the properties of low-pressure operation, high permeate flow. With excellent desalination and is applicable to the desalination of brackish water. Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry. Owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.Being suitable for desalting such water sources as surface water, underground water, tap water, and municipal water, etc., the Vontron Membrane Range is mainly applicable to the treatment of various industrial water such as industrial-purpose pure water, boiler water replenishment in power plants, and can be also applied to such brackish water applications, such as treatment of high-concentration saline wastewater and production of beverage-purpose water.
4d
Mbombela / Nelspruit1
R 303.60
SavedSave
Please note that shipping and installation is not included.Membrane Housing 3012
Type
3012 Reverse Osmosis Membrane Housing
Cap Color
White
Housing Color:
White
Operating pressure
Max. 125 PSI
Operating temperature
4 ~ 38℃(40 ~ 100℉)
Membrane Housing 3013
Model Number:
3013 model
Color:
White/grey
Usage:
filter housing for loading membrane
Product name:
3013 membrane housing
Size:
3.0 inch & 13 inch
Material:
Food-grade Plastic PP
Capacity:
400-600 GPD membrane available
Function:
work with flow restrictor +one way valve
Item name:
pressure vessel 3013 400 RO membrane housing
Use:
Household Pre-Filtration
Certification:
ce
Type:
Reverse Osmosis
Membrane housing 3012/3013
Our membrane housings are designed and manufactured to accept spiral/hollow fiber/ceramic and tuber membranes. They are used in commercial water treatment and industrial liquid treatment worldwide.
Commercial Water TreatmentPharmaceutical water treatmentDialysis water treatmentDairy ProductsFood and BeverageMining wastewater treatmentSpecial separationThis reverse osmosis membrane element equips direct-process domestic reverse osmosis equipment to provide consistent performance with long service life. It is compatible with all 3013 membrane holders.This membrane is intended to operate in an osmosis system with a direct flow, without a tank.Notes: Permeate of a single element may vary within [-20%] ~ [+20%] Dimensions: 1.0 inch = 25.4 mm
3d
Mbombela / Nelspruit1
R 2,467.85
SavedSave
Please note that shipping and installation is not included.Vontron Reverse-Osmosis Membrane ULP21-2540
The LP (low pressure) series of aromatic polyamide compound membrane element developed by Vontron Technology Co., Ltd. has the properties of low-pressure operation, high permeate flow, and excellent desalination and is applicable to the desalination of brackish water. Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry owing to its excellent performance in removing soluble salts, TOC, SiO2, etc. Being suitable for desalting such water sources as surface water, under ground water, tap water, and municipal water, etc., the LP series is mainly applicable to the treatment of various industrial water such as industrial-purpose pure water, boiler water replenishment in power plants, and can be also applied to such brackish water applications, such as treatment of high-concentration saline wastewater and production of beverage-purpose water.
Vontron Reverse-Osmosis Membrane ULP21-2540 Testing Conditions:
Testing Pressure………………………………………… 225 psi (1.55Mpa)The temperature of Testing Solution………………………… 25 °CThe concentration of Testing Solution (NaCl)……………… 2000ppmpH Value of Testing Solution…………………………… 7.5Recovery Rate of Single Membrane Element…………… 15%Operation limits and conditionsMax. Working Pressure………………………………… 600psi (4.14Mpa)Max. Feed water Flow…………………………………… 75gpm (17 m3/h) (for 8040)Max. Feed water Temperature…………………………… 45 °CMax. Feed water SDI………………………………………5Residual chlorine Concentration of Feed water……………<0.1ppmpH Range of Feed water during Continuous Operation……3~10pH Range of Feed water during Chemical Cleaning………2~12Max. Pressure Drop of Single Membrane Element……… 15psi (0.1Mpa)
Vontron Reverse-Osmosis Membrane ULP21-2540 Important Information Any specific application must be limited within the Operating Limits and Conditions. We strongly recommend you to refer to the latest edition of the technology manual and design guide prepared by Vontron Technology Co., Ltd., or consult experts proficient in membrane technology.
4d
Mbombela / Nelspruit10
R 3,900
NEGOTIABLE
SavedSave
Installation type: rooftop mount
Capacity: 300L
Number of heat tubes: 30
Power rating of electric element: 2000W
When installed in direct sunlight, away from any shade, then the electric
element never needs to be switched on to heat up the water, as the sun alone
can get the water temperature to boiling hot. So make sure trees around the
solar geyser are always pruned
This 300L solar geyser was installed in August 2012 but now the hole at the
bottom of the tank, next to the anode access hole, has rusted through.
R3900 for the unit as a whole
R240 per heat tube
R1200 for 10x tubes
R2400 for 30x tubes
To be collected in Vuurklip Street, Die Wilgers, Pretoria East.
Contact Ursula for collection or to arrange a viewing.
21d
Eastern Pretoria1
R 242.19
SavedSave
Please note that shipping and installation is not included.Specifications and Major Properties of the 1812 50 GPD Vontron Membrane:Active Membrane Area ft²(m²): 3.5(0.32)Average Permeated Flow: 50 GPDStable Rejection Rate: 97.5%Minimum Rejection Rate: 96.0%
Testing Conditions:
Testing Pressure 60 psi (0.41Mpa)Temperature of Testing Solution 25°CConcentration of Testing Solution (NaCl) 250ppmpH Value of Testing Solution 7.5Recovery Rate of Single Membrane Element 15%
Extreme Operation Conditions:Max. Working Pressure: 300psi(2.07Mpa)Max. Feed water Temperature: 45°CMax. Feed water SDI: 5Free Chlorine Concentration of Feed water <0.1ppmpH Range of Feed water during Continuous Operation: 3~10pH Range of Feed water during Chemical Cleaning: 2~12Max. Pressure Drop of Single Membrane Element: 10psi (0.07Mpa)
The Vontron Membrane Range developed by Vontron Technology Co. Ltd. has the properties of low-pressure operation, high permeate flow. With excellent desalination and is applicable to the desalination of brackish water. Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry. Owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.Being suitable for desalting such water sources as surface water, underground water, tap water, and municipal water, etc., the Vontron Membrane Range is mainly applicable to the treatment of various industrial water such as industrial-purpose pure water, boiler water replenishment in power plants, and can be also applied to such brackish water applications, such as treatment of high-concentration saline wastewater and production of beverage-purpose water. 1812 50 GPD Vontron Membrane.
3d
Mbombela / Nelspruit1
R 260.82
SavedSave
Please note that shipping and installation is not included.Specifications and Major PropertiesActive Membrane Area ft²(m²): 3.5(0.32)Average Permeated Flow: 75 GPDStable Rejection Rate: 97.5%Minimum Rejection Rate: 96.0%
Testing Conditions:
Testing Pressure 60 psi (0.41Mpa)Temperature of Testing Solution 25°CConcentration of Testing Solution (NaCl) 250ppmpH Value of Testing Solution 7.5Recovery Rate of Single Membrane Element 15%
Extreme Operation Conditions:
Max. Working Pressure: 300psi(2.07Mpa)Max. Feed water Temperature: 45°CMax. Feed water SDI: 5Free Chlorine Concentration of Feed water <0.1ppmpH Range of Feed water during Continuous Operation: 3~10pH Range of Feed water during Chemical Cleaning: 2~12Max. Pressure Drop of Single Membrane Element: 10psi(0.07Mpa)
Vontron Membrane 1812 75 GPD
The Vontron Membrane Range developed by Vontron Technology Co. Ltd. has the properties of low-pressure operation, high permeate flow. With excellent desalination and is applicable to the desalination of brackish water. Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry. Owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.Being suitable for desalting such water sources as surface water, underground water, tap water, and municipal water, etc., the Vontron Membrane Range is mainly applicable to the treatment of various industrial water such as industrial-purpose pure water, boiler water replenishment in power plants, and can be also applied to such brackish water applications, such as treatment of high-concentration saline wastewater and production of beverage-purpose water.
3d
Mbombela / Nelspruit1
R 242.19
SavedSave
Please note that shipping and installation is not included.Specifications and Major Properties of the 1812 50 GPD Vontron Membrane:Active Membrane Area ft²(m²): 3.5(0.32)Average Permeated Flow: 50 GPDStable Rejection Rate: 97.5%Minimum Rejection Rate: 96.0%
Testing Conditions:
Testing Pressure 60 psi (0.41Mpa)Temperature of Testing Solution 25°CConcentration of Testing Solution (NaCl) 250ppmpH Value of Testing Solution 7.5Recovery Rate of Single Membrane Element 15%Extreme Operation Conditions:
Max. Working Pressure: 300psi(2.07Mpa)Max. Feed water Temperature: 45°CMax. Feed water SDI: 5Free Chlorine Concentration of Feed water <0.1ppmpH Range of Feed water during Continuous Operation: 3~10pH Range of Feed water during Chemical Cleaning: 2~12Max. Pressure Drop of Single Membrane Element: 10psi (0.07Mpa)
The Vontron Membrane Range developed by Vontron Technology Co. Ltd. has the properties of low-pressure operation, high permeate flow. With excellent desalination and is applicable to the desalination of brackish water. Besides, it is particularly applicable to the fabrication of high-purity water for the electronic industry and electric power industry. Owing to its excellent performance in removing soluble salts, TOC, SiO2, etc.Being suitable for desalting such water sources as surface water, underground water, tap water, and municipal water, etc., the Vontron Membrane Range is mainly applicable to the treatment of various industrial water such as industrial-purpose pure water, boiler water replenishment in power plants, and can be also applied to such brackish water applications, such as treatment of high-concentration saline waste water and production of beverage-purpose water. 1812 50 GPD Vontron Membrane.
3d
Mbombela / NelspruitSave this search and get notified
when new items are posted!
