Mecer Galleon II 3-phase 10Kva 10Kw Online Tower UPS ME-10K-GA33Features True double-conversion DSP technology guarantees high performance Output power factor 1 Active power factor correction in all phases 50Hz/60Hz frequency converter mode ECO mode operation for energy saving (ECO) Emergency power off function (EPO) Generator compatible SNMP+USB+RS-232 multiple communications 3-stage extendable charging design for optimized battery performance Adjustable battery numbers for long-run model Maintenance bypass available Parallel operation with commom battery Power walk-in function *Optional parallel operation *Optional isolation transformer offers full isolation and complete common mode noise rejection Technical SpecificationProduct: Mecer Galleon II 3-phase UPSPhase: 3-phase in/3-phase outCapacity: 10KVA/10KWParallel Capability: Up to 4 unitsINPUT Nominal Voltage: 3X400Vac(3Ph+N)/230Vac(1Ph=N) Voltage Range: 110-300 VAC @ 50% loadï¼›176-276 VAC @ 100% load Frequency Range: 46-54Hz or 56-64Hz Power Factor: 0.99 @ 100% load Harmonic Distortion (THDi): OUTPUT Output Voltage: 3 x380/400/415 VAC (3Ph+N) or 208/220/230/240 VAC (1Ph+N) AC Voltage Regulation (Batt. Mode): ± 1% Frequency Range (Synchronized Range): 46-54Hz or 56-64Hz Frequency Range (Batt. Mode): 50/60 Hz ± 1% or 60Hz ± 0.1 Hz Current Crest Ratio: 3:1 (max.) Harmonic Distortion (THDv): 2% THD (Linear Load) , 5% THD (Non-linear Load)Transfer Time AC mode to Battery mode: Zero Inverter to Bypass: Zero Waveform (Batt. Mode): Pure Sine WaveOverload Capability AC mode: 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Battery Mode: 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately BYPASS Nominal Voltage: 3 x 380/400/415 VAC (3Ph+N) Voltage Range: -30% to +20% (Adjustable) Frequency Range (Synchronized Range): 46-54Hz or 56-64Hz Overload Capability: > 130% 1 minute (default)Continously working until breaker protection (optional)BATTERY Battery Type: 12V/9Ah Numbers: (10+10)pcs Typical Recharge Time: 4 hours recover to 90% capacity Charging Current (max.): 2A (Adjustable) Charging Voltage: +/-13.65V*N (N=10)INDICATORSLCD Panel: UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions MANAGEMENT Smart RS-232/USB: Supports Windows® Family, Linux and MAC Optional SNMP: Power management from SNMP manager and web browserDimension, D X W X H (mm): 630 x 250 x 826Weight: 103 kg *When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%.**If the UPS is installed or used in a place where the altitude is higher than maximum height, the output power will be derated 1% per 100m.. Copy this link to view or buy:https://www.firstshop.co.za/products/mecer-galleon-...Stock Code: ME-10K-GA33Items Available: 1Stock ID: ME-10K-GA33
1mo
1
R 2,000
SavedSave
Used for less than a year then upgraded to Lithium setup.
Call/Whatsapp David
0605053557
3h
3
R 350
SavedSave
Mecer ups 1000va 600wbattery not included unit can be converted to be use for load shedding. Will run tv, dstv, WiFi , lights etc 0764966821 or WhatsApp R350
6h
1
R 34,399
SavedSave
Mecer Galleon II 3-phase 10Kva 10Kw Online Tower UPS ME-10K-GA33Features True double-conversion DSP technology guarantees high performance Output power factor 1 Active power factor correction in all phases 50Hz/60Hz frequency converter mode ECO mode operation for energy saving (ECO) Emergency power off function (EPO) Generator compatible SNMP+USB+RS-232 multiple communications 3-stage extendable charging design for optimized battery performance Adjustable battery numbers for long-run model Maintenance bypass available Parallel operation with commom battery Power walk-in function *Optional parallel operation *Optional isolation transformer offers full isolation and complete common mode noise rejection Technical SpecificationProduct: Mecer Galleon II 3-phase UPSPhase: 3-phase in/3-phase outCapacity: 10KVA/10KWParallel Capability: Up to 4 unitsINPUT Nominal Voltage: 3X400Vac(3Ph+N)/230Vac(1Ph=N) Voltage Range: 110-300 VAC @ 50% loadï¼›176-276 VAC @ 100% load Frequency Range: 46-54Hz or 56-64Hz Power Factor: 0.99 @ 100% load Harmonic Distortion (THDi): OUTPUT Output Voltage: 3 x380/400/415 VAC (3Ph+N) or 208/220/230/240 VAC (1Ph+N) AC Voltage Regulation (Batt. Mode): ± 1% Frequency Range (Synchronized Range): 46-54Hz or 56-64Hz Frequency Range (Batt. Mode): 50/60 Hz ± 1% or 60Hz ± 0.1 Hz Current Crest Ratio: 3:1 (max.) Harmonic Distortion (THDv): 2% THD (Linear Load) , 5% THD (Non-linear Load)Transfer Time AC mode to Battery mode: Zero Inverter to Bypass: Zero Waveform (Batt. Mode): Pure Sine WaveOverload Capability AC mode: 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Battery Mode: 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately BYPASS Nominal Voltage: 3 x 380/400/415 VAC (3Ph+N) Voltage Range: -30% to +20% (Adjustable) Frequency Range (Synchronized Range): 46-54Hz or 56-64Hz Overload Capability: > 130% 1 minute (default)Continously working until breaker protection (optional)BATTERY Battery Type: 12V/9Ah Numbers: (10+10)pcs Typical Recharge Time: 4 hours recover to 90% capacity Charging Current (max.): 2A (Adjustable) Charging Voltage: +/-13.65V*N (N=10)INDICATORSLCD Panel: UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions MANAGEMENT Smart RS-232/USB: Supports Windows® Family, Linux and MAC Optional SNMP: Power management from SNMP manager and web browserDimension, D X W X H (mm): 630 x 250 x 826Weight: 103 kg *When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%.**If the UPS is installed or used in a place where the altitude is higher than maximum height, the output power will be derated 1% per 100m.. Copy this link to view or buy:https://www.firstshop.co.za/products/mecer-galleon-...Stock Code: ME-10K-GA33Items Available: 1Stock ID: ME-10K-GA33
1mo
2
R 600
NEGOTIABLE
SavedSave
- 2000VA/1200W Line Interactive UPS- Microprocessor control guarantees high reliability- Boost and buck AVR for voltage stabilization- Auto restart while AC is recovering- Simulated sine wave- Off-mode charging- Cold start function- USB communication port and RJ-11/RJ-45 protection- Overload, discharge, and overcharge protection- Supports Windows 2000 / 2003 / 2008 / XP / Vista / 7 / 8, Linux, Unix, and MAC
1d
1
R 8,899
SavedSave
Mecer Winner Pro 3000VA 2U On-Line Rackmount UPS 83-321163-01G. Copy this link to view or buy:https://www.firstshop.co.za/products/mecer-winner-pro-3000va-2u-on-line-rackmount-ups-83-321163-01g-149254?variant=42472719483044Stock Code: 83-321163-01GItems Available: 1Stock ID: 83-321163-01G
1mo
1
R 8,899
SavedSave
Mecer Winner Pro 3000VA 2U On-Line Rackmount UPS 83-321163-01G. Copy this link to view or buy:https://www.firstshop.co.za/products/mecer-winner-pro-3000va-2u-on-line-rackmount-ups-83-321163-01g-149254?variant=42472719483044Stock Code: 83-321163-01GItems Available: 1Stock ID: 83-321163-01G
1mo
8
R 9,950
NEGOTIABLE
SavedSave
Mecer ME-10000-GTU 10000VA / 8000W UPS-A42753 ,1 available, priced per item. We are a second hand shop with branches in Milnerton and Montague Gardens. Large selection of goods under one roof. 2ndhandwarehouse.com
4d
R 1,200
SavedSave
Mecer 2000VA OFF-LINE UPSMecer 2000VA OFF-LINE UPS (with AVR,Monitoring Software + Cable & Built-in Surge Protection) - Black, No Power cable included Features:2000VA line interactive UPSMicroprocessor control guarantees high reliabilityBoost and buck AVR for voltage stabilizationAuto restart while AC is recoveringSimulated sine waveOff-mode chargingCold start functionUSB communication port and RJ-11/RJ-45 protectionOverload, discharge, and overcharge protectionSupports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
8d
4
R 1,000
NEGOTIABLE
SavedSave
OVERVIEWPlease note that the original 12V battery is not included, but you can get a brand new one fairly cheaply nowadays (less than R3000), which will allow you to own a fantastic loadshedding buster for less than R4000 all together - where else can you find such a deal? (Answer: nowhere else, only here by me!)This Lalela trolley with a Mecer 720W Simulated Sine Wave inverter is in absolute fantastic condition, with hardly any sign of use. It has been kept well, and used lightly for just about two years. It is a semi-UPS solution, in that when it is turned on, it kicks in immediately once the power cuts, without you having to worry about it!It is a plug and play solution: you only need a vehicle to take it with you, and to add your own battery, and you are good to go! Only selling this because of an upgraded system.During a four-hours loadshedding, you can run a lot of electronics concurrently on it with no issue, such as:- Wi-Fi router- 1 x TV- 2 x Laptops- 2 x phones charging- Some more electronic stuffNo shipping/deliveries, collections only.DISCLAIMER: Please note that everything I am selling works perfectly and as intended as of the moment of sale. I however cannot provide any warranty for anything that may arise after the sale.
15d
8
R 9,950
NEGOTIABLE
SavedSave
Mecer ME-10000-GTU 10000VA / 8000W UPS-A42753 ,1 available, priced per item. We are a second hand shop with branches in Milnerton and Montague Gardens. Large selection of goods under one roof. 2ndhandwarehouse.com
17d
10
Contact f/price
SavedSave
Mecer & RCT 1Kw & 2Kw pure sinewave inverters will keep your home office/small biz going during load-shedding. Plug in to your wall plug for charging when power is up. Ideal for a small office/home office/home living room - enough to keep your PC or laptop, router, TV and a LED light or two going while the power is down. Alternative options are Mecer modified sinewave inverters or Ecoflow portable power stations Note - not for use with geysers, kettles, laser printers, stoves (anything with a element). Contact us for pricing/stock availability or for larger solar systems. We Supply UPS, power packs, solar panels and accessories. Message us with your requirement.
25d
3
Negotiable
NEGOTIABLE
SavedSave
The ups is working but requires new batteries for use. the system takes 2 batteries so please check the prices before purchasing the system. Make me an offer
1mo
6
R 9,950
NEGOTIABLE
SavedSave
Mecer ME-10000-GTU 10000VA / 8000W UPS-A42753 ,1 available, priced per item. We are a second hand shop with branches in Milnerton and Montague Gardens. Large selection of goods under one roof. 2ndhandwarehouse.com
1mo
2
R 8,500
SavedSave
Mixed UPS units, Mecer, etc:3 x 2000va5 x 1000vaAll units have been serviced and had new bateries put in them. Selling them as a package.
15d
2
R 2,300
SavedSave
Stock available
Mecer 1200VA (720W) Inverter Battery Charger (UPS) - Intelligent Fan
Features:
- Simulated sine wave inverter
- Built-in AVR for voltage regulation
- Wide input voltage range: 90-280 VAC
- 12VDC available
- Overload and short circuit protection
- LCD display for comprehensive information
Specifications:
- MODEL Mecer IVR-1200LBK
- CAPACITY 1200 VA / 720 W
- POWER FACTOR 0.8
- Input Voltage range 90-280VAC
Line Mode:
- Output Voltage
- Bypass mode: 0utput voltage same as input voltage
- AVR mode: Output voltage = Input voltage 1.2 at Input voltage - Output Frequency Same as input
Battery Mode (BATTERIES NOT INCLUDED):
- Output Voltage 230Vac +/-10%
- Transfer Time 20ms typical
- Waveform Modified Sine-wave
Overload Capability:
- Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
- Load >130% +/-15%, fault immediately.
- AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
- AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
- Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.
Short Circuit Protection:
- Line Mode Breaker
- Battery Mode Current limit +Firmware Protection
Battery specs needed (NOT INCLUDED):
- Battery Voltage 12VDC
- Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery
- Polarity Reserve Protection Yes
- Charger available I/P range 90 280V
Charger:
- Constant Current Charger Voltage 14.3VDC +/-2%
- Floating Charge Voltage 13.7VDC +/-2%
- Maximum Charge Current 10A or 20A
- DC Start Voltage >11VDC
Physical:
- Dimension, D X W X H (mm) 350 x 90 x 300
- Net Weight (kgs) 4.5
Environment:
- Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
- Operating Temperature 0 degrees C to 40 degrees C
- Storage Temperature -15 degrees C to 50 degrees C
2mo
VERIFIED
1
R 11,500
SavedSave
Free Delivery within SA. 3 Year warranty. This is only an inverter. No batteries supplied. System can function without battery if sufficient solar is available. KODAK Solar Off-Grid Inverter King with UPS 5kW 48V (Similar to MECER SOL-I-AX-5K)Part No: OG-PLUS5.48 Storage Systems - Hybrid Inverter - Off-GridIn rural or end-of-line locations, the AC grid voltage can fluctuate across a wide range. Voltage that is sufficiently far from the nominal 230V can cause appliances to run much less efficiently, or make them unable to function. Most other inverters that are capable of running in Island Mode simply pass through the variable grid voltage and only produce a smooth 230V supply in the event of a grid failure. Kodak's King Off-Grid inverter is perfect for areas where grid electricity is less stable because it produces smooth 230V AC at all times, whether the grid is available or not.This is great for efficient running of appliances, but crucial for an uninterrupted supply for important loads such as servers or ATMs. Built-in Bluetooth for mobile monitoring. Detachable LCD control module with multiple communications (Android App is available)Supports USB On-the-Go functionReserved communication port for BMS (RS485, CAN-BUS or RS232)Configurable AC/PV output usage timer and prioritizationParallel operation up to 9 unitsRobust UPS (uninterrupted power supply) for essential loads with zero transfer timeNote: The Kodak King inverter has a CAN-bus port included, which means a direct connection to Plyontech batteries is possible. Therefore no other control module, such as the ICC, is needed. Benefits over 5kVA MKS and MKS II:Bluetooth connectivity (Mobile App)Zero (0ms) transfer time is ideal for critical equipment like servers and medical equipmentGreat for voltage fluctuations. Voltage range 110-280 VACAxpert king password for bluetooth - 123456Weight:12 kgRated Power:5,000 WMin PPT Voltage:120 VMax PPT Voltage:430 VDC Startup Voltage:120 VDC Shutdown Voltage:120 VMax Input Voltage:450 VMax DC Power:4,500 WMax AC Power (5 Minutes):5,000 WSurge AC Power (1 Second):10,000 WMax DC Current:18 AMax DC Inputs:1Has DC Fuses:0Connector:Screw Terminal Included Connectors:1Euro Efficiency:93 %Transformer:NoneIP Rating:IP20MPPT Quantity :1Has Integrated DC Switch:NoWarranty:3 years
6mo
2
R 3,000
SavedSave
In Stock
Mecer 2400VA (1440W) Inverter Battery Charger (UPS) - Intelligent Fan
Features:
- Simulated sine wave inverter
- Built-in AVR for voltage regulation
- Wide input voltage range: 90-280 VAC
- 24VDC
- Overload and short circuit protection
- LCD display for comprehensive information
Specifications:
- MODEL: Mecer IVR-2400LBK
- CAPACITY: 2400 VA / 1440 W
- POWER FACTOR: 0.6
- Input Voltage range 90-280VAC
Line Mode:
- Output Voltage
- Bypass mode: 0utput voltage same as input voltage
- AVR mode:Output voltage = Input voltage 1.2 at Input voltage
Battery Mode:
- Output Voltage 230Vac +/-10%
- Transfer Time 20ms typical
- Waveform Modified Sine-wave
Overload Capability:
- Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
- Load >130% +/-15%, fault immediately.
- AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
- AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
- Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.
Short Circuit Protection:
- Line Mode Breaker
- Battery Mode Current limit +Firmware Protection
Battery:
- Battery Voltage 24 VDC
- Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge
- Polarity Reserve Protection Yes
- Charger available I/P range 90~280V
Charger:
- Constant Current Charger Voltage 28.6VDC +/-2%
- Floating Charge Voltage 27.4VDC +/-2%
- Maximum Charge Current 10A or 20A
- DC Start Voltage >22VDC
Physical:
- Dimension, D X W X H (mm) 350 x 90 x 300
- Net Weight (kgs) 5.5
Environment:
- Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
- Operating Temperature 0 degrees C to 40 degrees C
- Storage Temperature -15 degrees C to 50 degrees C
2mo
VERIFIED
1
R 2,150
SavedSave
Item in excellent condition, hardly used now due to having installed an inverter
8mo
VERIFIED
3
R 2,499
SavedSave
Stock clearence
Mecer 1200VA, 720W, 12V DC-AC Inverter only R2499.00
Mecer 2400VA, 1440W, 24V DC-AC Inverter only R2999.00
Mecer 1200VA, 1000W, 12V DC-AC Solar Inverter only R3199.00
Mecer 2400VA, 1800W, 24V DC-AC Solar Inverter only R3399.00
Cables to connect the unit to a battery are included.
A 220V power cable is included to recharge the battery while the power is on.
May be used as an inverter (to power 220V devices such as TVs from a battery) or a UPS (runs the device from the standard 220V power while the battery charges)
*EXTERNAL BATTERY REQUIRED*